Water monitoring for businesses
the documentation the law requires

Hotels, hospitals, production plants and public buildings have statutory obligations regarding water quality, and managers of housing associations must analyse the risks of their water systems. Working with the GBA Polska laboratory (PCA AB 1467), MICHLOR carries out full Group A and B monitoring, with documentation for Sanepid.

A+Bfull monitoring
PCAaccreditation AB 1467
3–4working days, microbiological results
✓documentation for Sanepid
Who does the obligation apply to?

Who must carry out water monitoring?

The obligation to monitor water quality follows from the Act on collective water supply, and the scope and frequency of testing are set by the Regulation of the Minister of Health of 22 May 2026 (Journal of Laws 2026, item 748). It applies to water suppliers and, since the amendment of the Act of 13 March 2026 (Journal of Laws 2026, item 605), also to owners and managers of priority premises, i.e. non-residential buildings whose water is used by more than 50 people a day.

Hotels and guesthouses

Priority premises: a risk assessment of the internal water system, to be submitted by 30 June 2028. Legionella in hot water once a year, and every 3 years after two consecutive good results. A hotel with its own water intake is also a water supplier and tests Group A.

Hospitals and care homes

Premises providing round-the-clock care are priority premises. Legionella in hot water: below 1,000 CFU/l, and where patients with weakened immunity stay, below 50 CFU/l, with testing every 6 months where devices generate aerosol.

Production plants

A plant whose water is used by more than 50 people a day is a priority premises and needs a risk assessment of its internal water system. A plant with its own drinking water intake is a water supplier and tests Groups A and B.

Housing associations and co-operatives

A residential building is not a priority premises. The manager carries out a general risk analysis of the water system (layout, hot water temperatures, materials, draw-off points) and reports unmet requirements or lead components to the sanitary inspectorate, which may recommend Legionella testing.

Scope of testing

Group A and Group B monitoring

The range of parameters follows from the Regulation of the Minister of Health of 22 May 2026 (Journal of Laws 2026, item 748), which implements EU Directive 2020/2184 on the quality of water intended for human consumption.

Group A monitoring (basic)

The parameters Sanepid requires to assess current water quality. Frequency: at least 1–4 times a year.

  • Escherichia coli (E. coli)
  • Intestinal enterococci
  • Coliform bacteria
  • Colony count at 22 °C
  • Colour, turbidity, taste, odour
  • pH and electrical conductivity
  • Free chlorine or chloramines, where water is disinfected
  • Ammonium and nitrites where chloramination is used
  • Aluminium and iron, where used in treatment

Group B monitoring (extended)

Covers Group A and all other parameters in the regulation. Frequency: at least once a year; after a risk assessment it can be reduced, but every parameter is tested at least once every 6 years.

  • All Group A parameters
  • Metals: lead, cadmium, arsenic, mercury, nickel, copper, chromium
  • Nitrates and nitrites
  • Pesticides
  • PAHs and benzo(a)pyrene
  • Trichloroethylene, tetrachloroethylene and trihalomethanes (THMs)
  • Bromates, chlorates and chlorites
  • PFAS total and bisphenol A (new from 2026)
  • Manganese, sulphates, chlorides, sodium
  • Cyanides, fluorides, boron
Full service

Complete monitoring
from sampling to documentation

MICHLOR takes on the whole process: the sampling schedule, transport to the GBA Polska laboratory, the analysis and preparation of the documentation required by the sanitary supervisory authorities.

At premises with process installations (boiler rooms, heat substations, cooling systems) we combine monitoring with chemical water conditioning — it keeps the parameters within limits and protects the system against corrosion and scale.

  • Preparation of an individual monitoring schedule for the property
  • Sampling in certified containers to PN-EN ISO 5667
  • Analysis at the GBA Polska laboratory (PCA accreditation AB 1467)
  • A report with the results set against the legal limits
  • Documentation in a format accepted by Sanepid and the sanitary inspectorate
  • A reminder when the next test is due
  • Corrective action where results exceed the limits
Questions and answers

Frequently asked questions about monitoring

What penalties apply for failing to monitor water at a property?

Failing to carry out the required water quality monitoring can result in an administrative decision from Sanepid ordering that testing be done and, where a hazard is identified, a decision to close the premises. The sanitary inspectorate can impose a fine or refer the matter to court. Regardless of any penalties, the owner bears full responsibility for any harm to health connected with the water at their premises.

How often does water in a hotel need testing?

A hotel with its own water intake is a water supplier and tests Group A: at least 4 times a year if it supplies more than 1,000 m³ a day, and 1–2 times a year if less. A hotel whose water is used by more than 50 people a day is a priority premises and tests its hot water for Legionella: once a year, and every 3 years after two consecutive results below 1,000 CFU/l.

Does MICHLOR prepare the documentation for Sanepid?

Yes. Reports from the GBA Polska laboratory (PCA AB 1467) are accepted by sanitary supervisory authorities throughout Poland. MICHLOR can prepare a complete water monitoring register for the property in the format Sanepid requires, covering all the required dates, parameters and results.

What is Legionella and why does it matter so much in monitoring?

Legionella pneumophila is a bacterium that grows in warm water (25–45°C) inside plumbing systems. It causes Legionnaires' disease — a severe pneumonia that is fatal in around 10–15% of cases. In communal residential premises (hotels, hospitals, halls of residence) detecting Legionella is one of the most serious sanitary hazards. MICHLOR carries out Legionella testing in partnership with GBA Polska and also disinfects water systems — more about Legionella control.

Ask for a quote

Monitoring quote
for your property

The scope and frequency of monitoring depend on the type of property and how much water it draws. We will prepare an individual quote once you briefly describe your needs.

  • A reply within 1 working day
  • A quote with no obligation
  • A schedule matched to Sanepid requirements
  • Documentation ready to submit to the authorities
  • An annual contract at a fixed price is available

Ask about water monitoring

We are here to help

Any questions?
Call or write to us.

We work throughout Poland and across Europe. We reply the same working day.

Free quote