Groups A and B · Sanepid-compliant · PCA accreditation AB 1467

Water monitoring for businesses
the documentation the law requires

Hotels, hospitals, production plants, housing associations and public buildings have a statutory obligation to monitor water quality. Working with the GBA Polska laboratory (PCA AB 1467), MICHLOR carries out full Group A and B monitoring — with documentation for Sanepid.

A+Bfull monitoring
PCAaccreditation AB 1467
24hmicrobiological results
documentation for Sanepid
Who does the obligation apply to?

Who must carry out water monitoring?

The Regulation of the Minister of Health of 7 December 2017 (Journal of Laws 2017, item 2294) places an obligation to monitor water quality on all producers and suppliers of water intended for human consumption.

Hotels and guesthouses

Your own water system serving guests = Group A monitoring required at least twice a year. Legionella — testing at least once a year.

Hospitals and clinics

Extended Group A + B monitoring and Legionella pneumophila. The documentation required by Sanepid and at sanitary inspections.

Production plants

Process and drinking water — monitoring is mandatory under the Ministry of Health regulation. Documentation required for the sanitary inspectorate and the State Sanitary Inspection.

Housing associations and co-operatives

Private water sources or systems serving more than 50 people — Group A monitoring is mandatory at least once a year.

Scope of testing

Group A and Group B monitoring

The range of parameters follows from the Regulation of the Minister of Health (Journal of Laws 2017, item 2294) and EU Directive 2020/2184 on the quality of water intended for human consumption.

Group A monitoring (basic)

The parameters Sanepid requires to assess current water quality. Frequency: at least 1–4 times a year.

  • Coliform bacteria, E. coli
  • Intestinal enterococci
  • Legionella spp. (hotels, hospitals)
  • pH, turbidity, colour, odour, taste
  • Free chlorine and chloramines
  • Total iron, manganese
  • Ammonium (NH₄⁺)
  • Nitrates (NO₃⁻)
  • Electrical conductivity
  • Water temperature

Group B monitoring (extended)

Covers all Group A parameters plus extended chemical testing. Frequency: once every 5 years or on request.

  • All Group A parameters
  • Heavy metals: lead (Pb), cadmium (Cd), arsenic (As), mercury (Hg)
  • Pesticides and herbicides
  • Polycyclic aromatic hydrocarbons (PAHs)
  • Trichloroethylene and tetrachloroethylene
  • Trihalomethanes (THMs)
  • Bromates and chlorates
  • Radioactive substances (radon, α and β activity)
  • Surfactants
  • Cyanides, fluorides
Full service

Complete monitoring
from sampling to documentation

MICHLOR takes on the whole process: the sampling schedule, transport to the GBA Polska laboratory, the analysis and preparation of the documentation required by the sanitary supervisory authorities.

At premises with process installations (boiler rooms, heat substations, cooling systems) we combine monitoring with chemical water conditioning — it keeps the parameters within limits and protects the system against corrosion and scale.

  • Preparation of an individual monitoring schedule for the property
  • Sampling in certified containers to PN-EN ISO 5667
  • Analysis at the GBA Polska laboratory (PCA accreditation AB 1467)
  • A report with the results set against the legal limits
  • Documentation in a format accepted by Sanepid and the sanitary inspectorate
  • A reminder when the next test is due
  • Corrective action where results exceed the limits
Questions and answers

Frequently asked questions about monitoring

What penalties apply for failing to monitor water at a property?

Failing to carry out the required water quality monitoring can result in an administrative decision from Sanepid ordering that testing be done and, where a hazard is identified, a decision to close the premises. The sanitary inspectorate can impose a fine or refer the matter to court. Regardless of any penalties, the owner bears full responsibility for any harm to health connected with the water at their premises.

How often does water in a hotel need testing?

A hotel supplying more than 1,000 m³ of water a day is subject to quarterly Group A monitoring. Smaller premises — at least once or twice a year. Legionella testing (Legionella pneumophila) is required at least once a year for all premises with a hot water system, including showers and decorative fountains.

Does MICHLOR prepare the documentation for Sanepid?

Yes. Reports from the GBA Polska laboratory (PCA AB 1467) are accepted by sanitary supervisory authorities throughout Poland. MICHLOR can prepare a complete water monitoring register for the property in the format Sanepid requires, covering all the required dates, parameters and results.

What is Legionella and why does it matter so much in monitoring?

Legionella pneumophila is a bacterium that grows in warm water (25–45°C) inside plumbing systems. It causes Legionnaires' disease — a severe pneumonia that is fatal in around 10–15% of cases. In communal residential premises (hotels, hospitals, halls of residence) detecting Legionella is one of the most serious sanitary hazards. MICHLOR carries out Legionella testing in partnership with GBA Polska and also disinfects water systems — more about Legionella control.

Ask for a quote

Monitoring quote
for your property

The scope and frequency of monitoring depend on the type of property and how much water it draws. We will prepare an individual quote once you briefly describe your needs.

  • A reply within 1 working day
  • A quote with no obligation
  • A schedule matched to Sanepid requirements
  • Documentation ready to submit to the authorities
  • An annual contract at a fixed price is available

Ask about water monitoring

We are here to help

Any questions?
Call or write to us.

We work across Mazovia, Łódź, Podlasie and the Lublin region. We reply the same working day.

Free quote